Journal Information
Vol. 82. Issue 1.
Pages 70-75 (January - February 2016)
Share
Share
Download PDF
More article options
Visits
5881
Vol. 82. Issue 1.
Pages 70-75 (January - February 2016)
Original article
Open Access
Hearing performance and voice acoustics of cochlear implanted children
Desempenho auditivo e acústica da voz de crianças com implante coclear
Visits
5881
Ana Cristina Coelhoa,
Corresponding author
anacrisccoelho@yahoo.com.br

Corresponding author.
, Alcione Ghedino Brasolottob, Maria Cecília Bevilacquab, Adriane Lima Mortari Moretb, Fayez Bahmad Júniora,c
a Hospital Universitário de Brasília (HUB/UnB), Brasília, DF, Brazil
b Department of Speech, Language and Hearing Sciences, Faculdade de Odontologia de Bauru, Universidade de São Paulo (USP), Bauru, SP, Brazil
c Post-Graduate Program in Health Sciences, Universidade de Brasília (UnB), Brasília, DF, Brazil
This item has received

Under a Creative Commons license
Article information
Statistics
Tables (5)
Table 1. Characteristics of the sample regarding the assessed data.
Table 2. Mean and standard deviation of the acoustic data of the sustained vowel (n=46), sequential speech (n=45) and spontaneous speech (n=47).
Table 3. Correlation of acoustic data of the sustained vowel with age, time of device use, voice detection threshold, hearing category and language category.
Table 4. Correlation of acoustic data of sequential speech with age, time of device use, voice detection threshold, hearing category and language category.
Table 5. Correlation of acoustic data of spontaneous speech with age, time of device use, voice detection threshold, hearing category and language category.
Show moreShow less
Abstract
Introduction

The voice of hearing-impaired individuals has been described extensively, and exhibits abnormalities in quality, articulation and resonance. Having an understanding of the aspects that may have an impact on voice characteristics of cochlear implant users is important for users and for professionals in this field.

Objective

To verify the existence of correlation between age, time of device use, voice detection threshold, hearing category score and language category score with acoustic data of voices of cochlear implanted children.

Methods

Retrospective study. Fifty-one children ranging in age from 3 years to 5 years and 11 months who unilaterally used cochlear implants participated. Acoustic analysis of the sustained vowel/a/, sequential speech and spontaneous speech was performed. The results were correlated with demographic data and hearing test results.

Results

Children with worse voice detection threshold showed higher frequency in the sustained vowel (p0.001) and in the spontaneous speech (p0.005).

Conclusion

There was a correlation between the voice detection threshold and the frequency values of the sustained vowel and spontaneous speech of the studied population.

Keywords:
Voice
Voice quality
Cochlear implant
Resumo
Introdução

A voz do indivíduo com deficiência auditiva tem sido amplamente caracterizada, estando comprometida em termos de tipo de voz, articulação e ressonância, sendo que o conhecimento dos aspectos que possam ter impacto nas características vocais de usuários de implante coclear é de suma importância para os usuários e profissionais da área.

Objetivo

Verificar a existência de correlação entre idade, tempo de uso, limiar de detecção de voz, escore da categoria de audição e escore da categoria de linguagem com dados acústicos de vozes de crianças com implante coclear.

Método

Estudo retrospectivo. Participaram 51 crianças usuárias de implante coclear com idade de 3–5 anos e 11 meses. Foi realizada análise acústica da vogal sustentada/a/, fala encadeada e conversa espontânea. Os resultados foram correlacionados com dados demográficos e resultados de testes auditivos.

Resultados

Crianças com pior desempenho no teste de detecção de voz apresentam voz mais aguda na vogal sustentada (p ≤ 0,001) e na conversa espontânea (p ≤ 0,005).

Conclusão

Houve correlação entre os limiares de detecção de voz e os valores de frequência na vogal sustentada e conversa espontânea na população estudada.

Palavras-chave:
Voz
Qualidade da voz
Implante coclear
Full Text
Introduction

The vocal behavior of children can vary considerably, and parameters such as resonance, pitch and loudness are essential for determining this performance and to identify voice abnormalities.1 The expected vocal standard in childhood includes fundamental frequency above 250Hz, high pitch, moderate to high intensity and abrupt vocal attack. Slight nasality, hoarseness and breathiness can be observed.2

In the child with hearing impairment, especially if pre-lingual, there is a flaw in auditory monitoring of the voice resulting in several deviations of vocal production, because in addition to neuromuscular control, hearing is important for good performance in oral communication. The auditory system is able to regulate voice parameters such as intensity, extension and frequency.3,4 Among other characteristics, the most common vocal disorders in hearing impaired individuals include unpleasant quality, strain, resonance imbalance, high frequency, altered breathing pattern and utterance with excessive variation.5–7

Especially when performed early in life, the cochlear implant is a most important advancement in the treatment of children with pre-lingual hearing impairment, and implanted children achieve better auditory perception of speech sounds, incidental appropriation of oral language, and better speech intelligibility and vocal production.8,9 However, despite the marked improvements after the implant, it is possible that users of such devices show a suboptimal voice quality.10 Therefore, understanding the physiological processes involved in voice control of CI users is a major challenge for the specialists working in this area.11

It is known that the results with cochlear implants are closely related to the age at which the child received the device.12 Additionally, follow-up of these children monitors the performance of hearing, language and speech in clinical and daily contexts, and the performance evaluation supplies data to define more accurately the hearing ability of each child,4 as well as their oral communication with respect to voice and speech.

In this study we question whether the vocal characteristics of cochlear implanted children are related to other demographic and hearing performance characteristics. Therefore, the aim of this study was to investigate the correlation between age, time of device use, voice detection threshold, hearing category score13 and language category score14 and acoustic data of voices of cochlear implanted children.

Method

This study was approved by the Ethics Committee in Research with Human Beings of the institution where it was held, under process N. 131/2010. All parents/guardians signed the free and informed consent form.

Fifty-one children with pre-lingual hearing impairment, who unilaterally used the Nucleus 24 Contour, Nucleus Freedom Contour, PulsarCI100 or SonataTI100 cochlear implants, participated in the study.

The inclusion criteria for participation in the study were severe or profound bilateral congenital sensorineural hearing loss, no intellectual or emotional impairments, participation in an auditory habilitation program in the city of origin, cochlear implantation before 36 months of age with full insertion of the electrodes and use of the CI for more than a year.

Considering the purpose of the study, speech samples were collected from participants, comprising the utterance of the vowel/a/three times, sequential speech (counting from 1 to 5) and spontaneous speech for subsequent acoustic analysis. The recording program used was Sony Sound Forge (Sony Pictures Digital Inc 8.0) with sampling rate of 44,100Hz, 16Bit, mono channel. The participant remained seated during the recording in an acoustically treated audiometric testing room. The sound card M-Audio Fast Track Pro and headset microphone AKG C512 positioned at 45° and with a distance of 3cm from the mouth were used.

Acoustic analysis was performed with the Multi Dimensional Voice Program, model 5105, version 2.5.2 (Kay Elemetrics), and Real Time Pitch, model 5121, version 2.5.2 (Kay Elemetrics). The selected acoustic parameters for analysis of the long vowel were:

  • Frequency measurements: fundamental frequency mean (f0) and standard deviation;

  • Long-term and short-term frequency disturbance measures: coefficient of variation of f0 (vf0) and jitter;

  • Long-term and short-term amplitude disturbance measures: coefficient of variation of the amplitude (vAm) and shimmer;

  • Noise measurements: vocal turbulence index (VTI), soft phonation index (SPI), harmonics-to-noise ratio (HNR) and degree of sub-harmonics (DSH).

The selected parameters for analysis of sequential speech and spontaneous speech samples were frequency measurements: frequency mean, frequency extension measured in Hertz (Hz), minimum frequency, maximum frequency, frequency standard deviation and frequency extension measured in semitones.

Data regarding age, time of cochlear implant use, free-field voice detection threshold (VDT), hearing category score and language category score were collected on the same day of the voice recording, during routine evaluations by speech therapists from the cochlear implant service of the institution where the study was carried out.

The selected variables are continuous and normally distributed. Therefore, the statistical test used for the analysis was Pearson's correlation with a 5% significance level. A classification scale was used, where the correlation of 0–20% is considered poor, 20–40% bad, 40–60% regular, 60–80% good and 80–100% excellent.

Results

This study found a correlation between age, time of device use, voice detection threshold, hearing category score and language category score with acoustic data of voices of cochlear implanted children. The data that characterize the study population are shown in Table 1. The mean results of the acoustic analysis of voice signals of the participants are shown in Table 2. Because not all children were able to perform the three utterances, there was a slight variation in the total number of each utterance.

Table 1.

Characteristics of the sample regarding the assessed data.

Data  Mean (±standard deviation) 
Age (months)  48.38 (±8.01) 
Time of cochlear implant use (months)  24 (±8.03) 
Voice detection threshold (dB)  24.23 (±4.94) 
Hearing category  3.55 (±1.3) 
Language category  3.14 (±1.8) 

SD, standard deviation; dB, decibel.

Table 2.

Mean and standard deviation of the acoustic data of the sustained vowel (n=46), sequential speech (n=45) and spontaneous speech (n=47).

Parameter  Sustained vowelMean (±SD)  Sequential speechMean (±SD)  Spontaneous speechMean (±SD) 
Mean f0 (Hz)  293.53 (±55.5)  –  – 
SD f (Hz)  7.78 (±4.08)  –  – 
vf0 (%)  278 (±1.48)  –  – 
Jitter (%)  1.3 (±1.02)  –  – 
vAm (%)  16.09 (±5.84)  –  – 
Shimmer (%)  3.19 (±1.17)  –  – 
VTI (%)  0.07 (±0.07)  –  – 
SPI (%)  5.61 (±4.69)  –  – 
NHR (%)  0.13 (±0.02)  –  – 
DSH (%)  2.16 (±3.12)  –  – 
Mean Freq (Hz)  –  296.14 (±24.39)  304.70 (±31.10) 
Extension (Hz)  –  165.83 (±50.35)  168.32 (±43.72) 
Min Freq (Hz)  –  213.24 (±24.87)  209.20 (±27.47) 
Max Freq (Hz)  –  372.23 (±28.99)  377.54 (±33.25) 
SD Freq (Hz)  –  34.04 (±15.27)  38 (±15.99) 
Extension (semitones)  –  9.69 (±2.79)  10.19 (±2.67) 

Mean f0, mean of the fundamental frequency; SD f0, standard deviation of the fundamental frequency; vf0, coefficient of variation of f0, coefficient of amplitude variation; VTI, voice turbulence index; SPI, soft phonation index; HNR, harmonics-to-noise ratio; DSH, degree of sub-harmonics; Mean Freq, mean frequency; Min Freq, minimum frequency; Max Freq, maximum frequency; SD Freq, Standard deviation of frequency; Hz, Hertz.

The results considered for discussion were those with correlation ≥40%, comprising regular, good and excellent correlations. Thus, it was observed that as the voice detection threshold increases, i.e., worsens, the mean of f0 in the sustained vowel (p0.001) and in spontaneous speech (p0.005) increases (Tables 3–5).

Table 3.

Correlation of acoustic data of the sustained vowel with age, time of device use, voice detection threshold, hearing category and language category.

Parameter  AgeTime of useVDTHearing categoryLanguage category
  Corr  p-Value  Corr  p-Value  Corr  p-Value  Corr  p-Value  Corr  p-Value 
Mean f0 (Hz)  −30.70%  0.036  −17.90%  0.23  53.80%a  0.001b  −12.80%  0.391  −14.90%  0.317 
SD f0 (Hz)  5.60%  0.708  19.70%  0.185  23.20%  0.174  −1.00%  0.947  −9.80%  0.513 
vf0 (%)  13.80%  0.354  21.80%  0.141  2.90%  0.868  19.10%  0.198  0.20%  0.989 
  27.10%  0.066  33.70%  0.021  −1.10%  0.949  26.50%  0.072  10.40%  0.486 
vAmp (%)  9.10%  0.544  2.60%  0.862  −38.20%  0.022  −18.90%  0.202  −5.10%  0.734 
Shim (%)  32.10%  0.028  38.10%  0.008  −11.60%  0.499  27.10%  0.065  15.80%  0.288 
VTI (%)  −11.80%  0.43  3.50%  0.813  35.60%  0.033  −3.60%  0.81  1.00%  0.946 
SPI (%)  16.20%  0.277  −3.80%  0.802  −12.20%  0.479  2.50%  0.867  4.50%  0.764 
NHR (%)  18.60%  0.211  25.70%  0.081  −11.70%  0.496  25.70%  0.081  16.80%  0.259 
DSH (%)  10.60%  0.48  8.90%  0.55  −11.30%  0.513  4.00%  0.792  −0.40%  0.979 

VDT, voice detection threshold; Mean f0, mean of the fundamental frequency; SD f0, standard deviation of the fundamental frequency; vf0, coefficient of variation of f0, coefficient of amplitude variation; VTI, voice turbulence index; SPI, soft phonation index; HNR, harmonics-to-noise ratio; DSH, degree of sub-harmonics; Hz, Hertz.

a

Corr40%.

b

p>0.05.

Table 4.

Correlation of acoustic data of sequential speech with age, time of device use, voice detection threshold, hearing category and language category.

Parameter  AgeTime of useVDTHearing categoryLanguage category
  Corr  p-Value  Corr  p-Value  Corr  p-Value  Corr  p-Value  Corr  p-Value 
Mean Freq (Hz)  −33.20%  0.026  −19.00%  0.212  26.00%  0.125  −20.20%  0.184  −17.10%  0.26 
Extension (Hz)  −11.50%  0.451  −14.30%  0.349  −2.20%  0.898  0.90%  0.953  −4.20%  0.783 
Min Freq (Hz)  −4.10%  0.787  8.30%  0.588  9.10%  0.598  −7.30%  0.634  3.80%  0.806 
Max Freq (Hz)  −24.90%  0.099  −23.50%  0.12  10.40%  0.545  −3.80%  0.805  −12.50%  0.412 
SD Freq (Hz)  −15.40%  0.319  −17.20%  0.264  7.60%  0.664  −9.70%  0.532  −23.60%  0.123 
Extension semitones  −12.20%  0.425  −20.70%  0.173  2.40%  0.887  0.20%  0.989  −11.80%  0.438 

VDT, voice detection threshold; Mean Freq, mean frequency; Min Freq, minimum frequency; Max Freq, maximum frequency; SD Freq, standard deviation of the frequency; Hz, Hertz.

Table 5.

Correlation of acoustic data of spontaneous speech with age, time of device use, voice detection threshold, hearing category and language category.

Parameter  AgeTime of useVDTHearing categoryLanguage category
  Corr  p-Value  Corr  p-Value  Corr  p-Value  Corr  p-Value  Corr  p-Value 
Mean Freq (Hz)  −13.40%  0.366  −5.50%  0.711  44.90%a  0.005b  −3.80%  0.796  −2.90%  0.846 
Extension (Hz)  2.70%  0.857  7.00%  0.635  7.90%  0.642  26.10%  0.073  16.60%  0.26 
Min Freq (Hz)  −13.20%  0.371  −18.60%  0.206  13.30%  0.433  −20.60%  0.16  −16.10%  0.273 
Max Freq (Hz)  −7.40%  0.615  −6.10%  0.681  19.70%  0.243  17.20%  0.241  8.40%  0.569 
SD Freq (Hz)  −5.40%  0.715  8.10%  0.584  13.40%  0.429  19.60%  0.182  12.50%  0.398 
Extension semitones  4.60%  0.755  10.00%  0.497  5.00%  0.767  25.00%  0.086  18.10%  0.218 

VDT, voice detection threshold; Mean Freq, mean frequency; Min Freq, minimum frequency; Max Freq, maximum frequency; SD Freq, standard deviation frequency; Hz, Hertz.

a

Corr ≥ 40%.

b

p > 0.05

Discussion

Acoustic analysis quantifies the sound signal and provides enough documentation to outline the baseline of the individual's voice; the acoustic parameters of fundamental frequency and their disturbance indices, along with measurements of noise, have important clinical implications.2 Among all analyzed acoustic parameters, only the fundamental frequency showed a correlation with the assessed demographics and hearing aspects. Although moderate, this correlation stands out, considering the value of p.

Among many other features, the literature shows a trend in which hearing-impaired individuals have high pitched voices, with this being the perceptual correlation of high fundamental frequency, which is caused by the lack of auditory feedback of one's own voice, as the frequency control is affected when auditory functions are impaired.4,15,16

The fundamental frequency is given by the glottic cycle numbers over a time unit (seconds). Their determinant factors are the natural length of the vocal folds, stretching, mass vibration and the involved tension.17 A high fundamental frequency reflects poor laryngeal control, also demonstrated by elevation of the larynx, higher phonation effort and incapacity to control the tension of the vocal folds and subglottic pressure.6

It is possible that the lack of auditory feedback by decreased auditory thresholds causes an increase in tension during the glottic cycle6 and a lack of control of the laryngeal musculature, thus increasing the values of the fundamental frequency. However, while several authors report that hearing impaired individuals often have difficulties in controlling laryngeal function,5–7,11,16 no studies were found in literature evaluating the laryngeal behavior of the hearing-impaired, that could provide a clearer understanding of the characteristics and adjustments of the vocal tract that result in the vocal changes described in this population.

In this study, it was observed that both in the sustained vowel and in spontaneous speech, the participants with worse voice detection threshold had the highest frequency. As the hearing loss increases or a hearing threshold obtained with a hearing aid worsens, the voice parameters tend to be more deviated.18 However, results from other studies that analyzed the fundamental frequency of CI5,11,19–23 users are controversial. Thus, we stress the importance of knowing all aspects that may have an impact on the vocal characteristics of cochlear implant users.

A previous study24 found a correlation between fundamental frequency values and the result of a speech perception test. A correlation has also been found between frequency values and the time of rehabilitation and age at surgery.11 A study assessing the variability in fundamental frequency4 showed that as the auditory threshold worsens, the variability of the fundamental frequency increases due to a decrease in auditory signals for the monitoring of vocal production. Studies carried out among the elderly have also shown that as the tone thresholds worsen, f0 increases.3,25

The impact of worsening hearing thresholds on the fundamental frequency measures has also been shown in studies that evaluated vocal production immediately after removing the auditory feedback provided by the CI.15

The other acoustic measures, including speech signal disturbances, utterance noise level and stability, did not correlate with the assessed data. Acoustic analysis of cochlear implant users demonstrated alterations of frequency and amplitude measures in short term with noise measurements within the normal range, and altered stability measures,11,20,23 with the results always associated with auditory feedback.

Understanding the physiological processes that contribute to vocal development in cochlear implanted children allows us to understand the speech production strategies in this population, attempting to establish goals for an adequate speech production.26 It is the auditory feedback that regulates the laryngeal musculature and postures of the vocal tract for an adequate phonation.20 Therefore, obtaining audiometric thresholds within the normal range for cochlear implant users is critical for vocal production control.

This study demonstrated the importance of understanding not only the vocal characteristics of cochlear implant users, but also with what factors these characteristics are correlated. This information is of great value for clinicians to increasingly ensure appropriate intervention regarding the vocal production of CI users.

Conclusion

For the assessed cochlear implanted children, there was a correlation between the voice detection thresholds and the frequency values for the sustained vowel and also in spontaneous speech. That allows us to affirm that the worse the voice detection threshold is, the more high-pitched is the child's voice. Other acoustic parameters did not correlate with the other assessed variables.

Conflicts of interest

The authors declare no conflicts of interest.

References
[1]
N.J. Sales, R. Queiroz Gurgel, M.I. Rebelo Gonçalves, A.C. Côrtes Gama, E. Oliveira Cunha, V.M. Prado-Barreto, et al.
Voice performance evaluation of street children from Aracaju, Brazil using perceptual-auditory and acoustic analyses.
[2]
M. Behlau, R. Azevedo, P. Pontes.
Conceito de voz normal e classificação das disfonias.
Voz: O livro do especialista – Volume I, pp. 53-79
[3]
G.S. Baraldi, L. Castro de Almeida, L.L. Calais, A.C. Borges, I. Gielow, M. Raymundo De Cunto.
Study of the fundamental frequency in elderly women with hearing loss.
Braz J Otorhinolaryngol, 73 (2007), pp. 378-383
[4]
G.S. Lee.
Variability in voice fundamental frequency of sustained vowels in speakers with sensorineural hearing loss.
[5]
N. Baudonck, E. D’haeseleer, I. Dhooge, K. Van Lierde.
Objective vocal quality in children using cochlear implants: a multiparameter approach.
[6]
S.L. Wirz, J.D. Subtelny, R.L. Whitehead.
Perceptual and spectrographic study of tense voice in normal hearing and deaf subjects.
Folia Phoniatr, 33 (1981), pp. 23-36
[7]
I. Hocevar-Boltezar, J. Vatovec, A. Gros, M. Zargi.
The influence of cochlear implantation on some voice parameters.
Int J Pediatr Otorhinolaryngol, 69 (2005), pp. 1635-1640
[8]
A.L. Moret, M.C. Bevilacqua, O.A. Costa.
Cochlear implant: hearing and language in pre-lingual deaf children.
Pro Fono, 19 (2007), pp. 295-304
[9]
L.B. de Souza, M.C. Bevilacqua, A.G. Brasolotto, A.C. Coelho.
Cochlear implanted children present vocal parameters within normal standards.
Int J Pediatr Otorhinolaryngol, 76 (2012), pp. 1180-1183
[10]
H.W. Hsu, T.J. Fang, L.A. Lee, Y.T. Tsou, S.H. Chen, C.M. Wu.
Multidimensional evaluation of vocal quality in children with cochlear implants: a cross-sectional, case-controlled study.
Clin Otolaryngol, 39 (2014), pp. 32-38
[11]
H.A. Guerrero Lopez, M. Mondain, B. Amy de la Bretèque, P. Serrafero, C. Trottier, M. Barkat-Defradas.
Acoustic, aerodynamic, and perceptual analyses of the voice of cochlear-implanted children.
J Voice, 27 (2013), pp. 523e1-5317e
[12]
N.B. Frederigue, M.C. Bevilacqua.
Otimização da percepção da fala em deficientes auditivos usuários do sistema de implante coclear multicanal.
Rev Bras Otorrinolaringol, 69 (2003), pp. 227-233
[13]
A.E. Geers.
Techniques for assessing auditory speech perception and lipreading enhancement in young deaf children.
Volta R, 96 (1994), pp. 85-96
[14]
L.T. Nascimento.
Uma proposta de avaliação da linguagem oral [Monografia de especialização].
Hospital de Pesquisa e Reabilitação de Lesões Lábio-Palatais, Universidade de São Paulo, (1997),
[15]
S.F. Poissant, K.A. Peters, M.P. Robb.
Acoustic and perceptual appraisal of speech production in pediatric cochlear implant users.
Int J Pediatr Otorhinolaryngol, 70 (2006), pp. 1195-1203
[16]
M. Behlau, R. Azevedo, M.I. Rehder, D.C. Thomé.
Disfonias congênitas.
Voz: O livro do especialista – Volume II, pp. 01-41
[17]
J.N. Braga, S.F.O. Domingos, T.M.M. Sampaio.
Frequência fundamental da voz de crianças.
Rev CEFAC, 11 (2009), pp. 119-126
[18]
J. Valero Garcia, J.M. Rovira, L.G. Sanvicens.
The influence of the auditory prosthesis type on deaf children's voice quality.
Int J Pediatr Otorhinolaryngol, 74 (2010), pp. 843-848
[19]
P. Campisi, A. Low, B. Papsin, R. Mount, R. Cohen-Kerem, R. Harrison.
Acoustic analysis of the voice in pediatric cochlear implant recipients: a longitudinal study.
Laryngoscope, 115 (2005), pp. 1046-1050
[20]
P. Campisi, A.J. Low, B.C. Papsin, R.J. Mount, R.V. Harrison.
Multidimensional voice program analysis in profoundly deaf children: quantifying frequency and amplitude control.
Percept Mot Skills, 103 (2006), pp. 40-50
[21]
M.K. Evans, D.D. Deliyski.
Acoustic voice analysis of prelingually deaf adults before and after cochlear implantation.
[22]
J. Allegro, B.C. Papsin, R.V. Harrison, P. Campisi.
Acoustic analysis of voice in cochlear implant recipients with post-meningitic hearing loss.
Cochlear Implants Int, 11 (2010), pp. 100-116
[23]
M.T. Ubrig, M.V. Goffi-Gomez, R. Weber, M.H. Menezes, N.K. Nemr, D.H. Tsuji, et al.
Voice analysis of postlingually deaf adults pre- and postcochlear implantation.
[24]
A.C. Coelho, M.C. Bevilacqua, G. Oliveira, M. Behlau.
Relationship between voice and speech perception in children with cochlear implant.
Pro Fono, 21 (2009), pp. 7-12
[25]
C.C. Weatherley, L.E. Worrall, L.M. Hickson.
The effect of hearing impairment on the vocal characteristics of older people.
Folia Phoniatr Logop, 49 (1997), pp. 53-62
[26]
M.B. Higgins, E.A. McCleary, A.E. Carney, L. Schulte.
Longitudinal changes in children's speech and voice physiology after cochlear implantation.

Please cite this article as: Coelho AC, Brasolotto AG, Bevilacqua MC, Moret ALM, Bahmad Júnior F. Hearing performance and voice acoustics of cochlear implanted children. Braz J Otorhinolaryngol. 2016;82:70–5.

Institution: Universidade de São Paulo, Faculdade de Odontologia de Bauru, Bauru, SP, Brazil; Universidade de Brasília, Faculdade de Ciências da Saúde, Brasília, DF, Brazil.

Copyright © 2015. Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial
Idiomas
Brazilian Journal of Otorhinolaryngology (English Edition)
Article options
Tools
en pt
Announcement Nota importante
Articles submitted as of May 1, 2022, which are accepted for publication will be subject to a fee (Article Publishing Charge, APC) payment by the author or research funder to cover the costs associated with publication. By submitting the manuscript to this journal, the authors agree to these terms. All manuscripts must be submitted in English.. Os artigos submetidos a partir de 1º de maio de 2022, que forem aceitos para publicação estarão sujeitos a uma taxa (Article Publishing Charge, APC) a ser paga pelo autor para cobrir os custos associados à publicação. Ao submeterem o manuscrito a esta revista, os autores concordam com esses termos. Todos os manuscritos devem ser submetidos em inglês.