Suggestions
Journal Information
Vol. 92. Issue 6.
(November - December 2026)
Cite
Cite
Share
Download PDF
More article options
Visits
398
Vol. 92. Issue 6.
(November - December 2026)
Original Article
Full text access

Remote analysis of auditory performance in cochlear implant users using a new tool: remote check

Visits
398
Francisco Wallison Lucena da Silvaa, Fernanda Ferreira Caldasb, Carolina Costa Cardosob, Ingrid Barros da Silva Santanaa, Rayssa Pacheco Brito Douradob, Fayez Bahmad Jra,b,*
Corresponding author
fayezbjr@gmail.com

Corresponding author.
a Universidade de Brasília (UnB), Brasília, DF, Brazil
b Instituto Brasiliense de Otorrinolaringologia, Brasília, DF, Brazil
Highlights

  • •

    Remote Check is feasible for describing the auditory profile of Cochlear Implant users.

  • •

    Remote Check can assist in the remote monitoring of Cochlear Implant users.

  • •

    Remote Check is a tool that can be used in clinical practice by the audiologist.

This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Tables (9)
Table 1. Descriptive statistics of categorical variables.
Tables
Table 2. Descriptive results in dB HL for prelingual and postlingual groups in speech-in-noise performance.
Tables
Table 3. Results of inferential analyses between unilateral and bilateral groups for speech-in-noise performance.
Tables
Table 4. Right ear auditory thresholds (dB HL) by frequency in the unilateral and bilateral CI groups.
Tables
Table 5. Left ear auditory thresholds (dB HL) by frequency in the unilateral and bilateral CI groups.
Tables
Table 6. Datalogging of CI users in unilateral and bilateral groups.
Tables
Table 7. Auditory performance in dB HL on the digit triplet test for unilateral and bilateral CI users.
Tables
Table 8. Right Ear results of inferential analyses between unilateral and bilateral groups.
Tables
Table 9. Left Ear results of inferential analyses between unilateral and bilateral groups.
Tables
Abstract
Objective

To evaluate and characterize the auditory performance of Cochlear Implant (CI) users through Remote Check tool via mobile device.

Methods

A prospective cross-sectional analytical study was carried out. Thirty-one cochlear implant users prelingual and postlingual participated in the study, with at least 6-months of implant use, without cognitive or intellectual changes associated with hearing loss. Remote Check was made available via the Nucleus Smart app and managed by the My Cochlear Professional platform. Participants responded to the test and data regarding Digit Triplets Test (DTT), Aided Threshold Test (ATT) and time of use were collected.

Results

Comparative tests indicated significant differences in speech-in-noise levels between groups of people with post-lingual and pre-lingual hearing loss. As for the hearing thresholds, significant difference was observed at different frequencies, varying according to use. In addition, the analysis of effect size showed moderate differences in speech in noise and some frequencies, and high effect at 250 Hz on left ear and device usage time for those wearing on right ear.

Conclusion

Remote Check is an effective tool that can assist in describing the profile of cochlear implant users. It was possible to trace the profile of CI users in the stage of datalogging, assessment of auditory thresholds and in speech-in-noise tests.

Level of evidence

2 (Step 2).

Keywords:
Auditory rehabilitation
Cochlear implant
Hearing Los
Remote check.
Full Text
Introduction

Cochlear Implant (CI) is an electronic device surgically inserted to restore hearing in individuals with severe to profound hearing loss who no longer benefit from hearing aids.1 CI use improves speech recognition, social interaction, cognitive stability, and overall quality of life.2 Individual auditory outcomes vary according to age, duration of deafness, residual hearing, and prior use of hearing aids.3 Cognitive aspects, particularly short-term memory, are also associated with post-implant performance.4

During the initial months of CI programming, the goal is to ensure audibility and user adaptation, with stable adjustments typically achieved after one year.5 Clinical assessment traditionally relies on tests conducted in an acoustic booth, such as Pure-Tone Audiometry (PTA) and Speech Recognition Threshold (SRT).6 However, hearing evaluation can also be conducted through Direct Audio Input (DAI) or Digital Audio Streaming (DAS), allowing signal transmission without an acoustic booth.7

Remote monitoring has become a valuable alternative, enabling distance follow-up of CI users. Remote Check (RC), developed by Cochlear™ and available within the Nucleus Smart App, provides a set of self-administered tests, questionnaires, and photo documentation, allowing patients or caregivers to perform assessments at home.8 These data are supervised by speech-language pathologists through the My Cochlear Professional (MCP) platform.

This study aimed to evaluate and characterize the auditory performance of unilateral and bilateral CI users through Remote Check using mobile devices.

Methods

This prospective cross-sectional analytical study was approved by the Ethics Committee (CAAE: 83476324.5.0000.5558). All participants provided informed consent. The research was conducted at a CI reference center in Faculty of Medicine of University of Brasília between September and December 2024.

Thirty-one CI users participated. Inclusion criteria comprised absence of cognitive deficits, at least six months of CI experience, and use of Nucleus 7, Nucleus 8, or Kanso 2 processors with Bluetooth connectivity. Remote Check was managed via My Cochlear Professional, an online platform that allows professionals to send and monitor remote assessments. Participants received instructions via WhatsApp on how to perform the tests (estimated duration 20–40 min) and were encouraged to complete them in a quiet environment. Assistance was available through messaging or in person. Upon completion, data collection was conducted by a single audiologist and individual reports were automatically generated through MCP and organized in spreadsheets for analysis.

Remote check components

Remote Check includes Implant Site Photos, Questionnaire, Aided Threshold Test (ATT), Digit Triplet Test (DTT), Impedance Check, and Usage Data. For this study, four components were analyzed:

  • •

    Usage Data: Logs on device-on time, volume, sensitivity, program use, and exposure to auditory environments.

  • •

    Digit Triplet Test (DTT): Determines speech perception in noise by presenting random digit sequences (1–9) at varying Signal-to-Noise Ratios (SNRs). Participants select the heard digits on the screen.

  • •

    Aided Threshold Test (ATT): Direct pure-tone stimuli (250 Hz–6 kHz) are streamed to the CI, and users indicate whether tones are audible or not, generating an audiogram.

Statistical analysis

Analyses were conducted using JASP. Descriptive statistics summarized categorical and numerical variables. Normality was assessed using the Shapiro–Wilk test.9 Independent-sample t-tests were applied for normally distributed data, and Mann–Whitney tests for non-normal data.10 Effect sizes were calculated using Cohen’s d or rank-biserial correlation, interpreted as small (≤0.2), moderate (0.2–0.5), or large (>0.5).11

Results

Remote Check procedures of each patient were completed during the estimated 20−40 min, with no additional time.

A total of 31 participants were included in the study. 11 participants were bilateral Cochlear Implant (CI) users (35.48%), whereas 20 were unilateral CI users (64.52%). Among the unilateral CI users, 18 had hearing loss in the contralateral ear. Of these, 8 had bimodal hearing (CI in one ear and a hearing aid in the other). 5 participants had undergone bilateral cochlear implantation but were using only one implant at the time of assessment. The remaining 5 participants did not use any hearing device in the contralateral ear despite meeting clinical indications for cochlear implantation. Only 2 participants presented with Single-Sided Deafness (SSD).

Participants' duration of CI use ranged from 2-years and 2-months to 24-years.

The mean age was 48.16-years, ranging from 15 to 79. Among the unilateral users, 11 had the implant on the left side (55.00%) and 9 on the right side (45.00%). Considering all participants, most of the sample was female (61.29%). In the bilateral CI user group, females accounted for 63.64%, while in the unilateral group, they represented 60.00%. Focusing only on the unilateral CI group, females made up 77.78% of those with a right-ear implant, while males represented 55.55% of those with a left-ear implant. Regarding the type of hearing loss, most cases were postlingual (64.52%), while prelingual cases accounted for 35.48%. The results are shown in Table 1.

Table 1.

Descriptive statistics of categorical variables.

Bilateral CI  Unilateral CI (Right)  Unilateral CI (Left)  Total 
SexFemale  7 (63.64%)  7 (77.78%)  5 (45.45%)  19 (61.29%) 
Male  4 (36.36%)  2 (22.22%)  6 (55.55%)  12 (38.71%) 
Onset of Hearing LossPrelingual  6 (54.55%)  1 (11.11%)  4 (36.36%)  11 (35.48%) 
Poslingual  5 (45.45%)  8 (88.89%)  7 (63.64%)  20 (64.52%) 

When comparing prelingual and postlingual hearing loss groups, the descriptive results are presented in Table 2.

Table 2.

Descriptive results in dB HL for prelingual and postlingual groups in speech-in-noise performance.

  Group  M  SD  Q1  Q2  Q3  Min  Max  p 
Bilateral (RE)Prelingual  −0.90  ‒  −0.90  −0.90  −0.90  −0.90  −0.90  ‒ 
Prelingual  −0.75  2.88  −2.78  −0.80  1.03  −4.30  3.20  0.64 
Bilateral (LE)Prelingual  −2.77  2.14  −3.55  −1.90  −1.55  −5.20  −1.20  0.31 
Prelingual  0.94  1.80  −0.70  1.50  1.80  −1.10  3.20  0.54 
Unilateral (RE)Prelingual  −0.63  1.47  −1.25  −0.35  0.28  −2.60  0.80  0.74 
Prelingual  −3.62  1.43  −4.60  −4.20  −2.20  −5.10  −2.00  0.22 
Unilateral (LE)  Prelingual  0.05  1.42  −0.78  −0.25  0.58  −1.30  2.00  0.65 

dB HL, Decibels Hearing Level; RE, Right Ear; LE, Left Ear; SD, Standard Deviation; Q1-Q3, Quartiles; M, Mean; Min, Minimum value; Max, Maximum value; p, Significance level from the Shapiro–Wilk test; p < 0.05.

Although some groups showed non-significant results in the Shapiro–Wilk test (indicating a normal distribution), nonparametric tests (Mann–Whitney) were chosen for the comparative analysis due to the number of participants in each group. The comparative tests indicated significant differences in speech-in-noise levels for left-ear between the groups with postlingual and prelingual hearing loss. This difference applies to both bilaterally and unilaterally implanted individuals (Table 3).

Table 3.

Results of inferential analyses between unilateral and bilateral groups for speech-in-noise performance.

  Side  U  p  rrb 
BilateralRight Ear  18  0.063  −0.800 
Left Ear  19  0.037  −0.900 
UnilateralRight Ear  ‒  ‒  ‒ 
Left Ear  0  0.036*  1.000 

dB HL, U: Mann–Whitney test statistic; p, Significance level; r rb, Rank-biserial correlation (effect size estimate for the Mann–Whitney test); p < 0.05.

Among users with unilateral cochlear implant, individuals with prelingual hearing loss showed poorer results compared to those with postlingual hearing loss. On the other hand, individuals with prelingual hearing loss in the group of bilateral cochlear implant users showed better results compared to participants with postlingual hearing loss in the same group.

Tables 4 and 5 presents descriptive statistics for numerical variables corresponding to the results at each sound frequency tested via the Remote Check. Auditory threshold assessments using Pure-Tone Audiometry (PTA), initially considering only bilateral cochlear implant users, revealed significant difference at 1 kHz, 4 kHz, and 6 kHz in the right ear, and at 1 kHz and 6 kHz in the left ear. In the unilateral cochlear implant group, significant difference were observed at 1 kHz, 2 kHz, 3 kHz, and 6 kHz among users with implants exclusively in the right ear. In contrast, users with unilateral implants in the left ear exhibited significant difference at 500 Hz, 1 kHz, 4 kHz, and 6 kHz.

Table 4.

Right ear auditory thresholds (dB HL) by frequency in the unilateral and bilateral CI groups.

    M  SD  Q1  Q2  Q3  Min  Max  p 
250 HzBi  19.03  6.04  14.91  17.66  21.08  12.83  33.50  0.058 
Uni  21.66  5.12  20.58  20.83  21.08  15.50  31.17  0.061 
500 HzBi  18.63  5.69  16.25  18.33  18.74  11.17  30.50  0.206 
Uni  18.98  5.35  16.67  18.17  20.16  11.38  28.83  0.552 
1 KHzBi  17.10  5.28  14.25  15.50  17.49  11.50  27.17  0.029 
Uni  16.16  4.28  14.41  14.83  15.83  12.86  26.50  <0.001 
2 KHzBi  18.42  5.57  14.17  18.00  21.66  10.33  26.21  0.184 
Uni  19.06  6.16  14.33  17.50  21.50  13.50  33.00  0.045 
3 KHzBi  18.75  4.28  15.50  17.50  19.50  14.50  26.83  0.125 
Uni  17.51  3.88  15.25  17.01  18.20  13.50  27.50  0.008 
4 KHzBi  17.64  6.70  15.17  16.17  16.83  12.10  34.50  0.001 
Uni  15.50  4.29  13.83  15.50  16.50  10.50  25.50  0.052 
6 KHzBi  17.27  6.25  14.50  15.50  17.17  12.50  32.83  0.002 
Uni  17.33  6.23  14.41  15.50  16.49  12.50  32.17  0.001 

dB HL, Decibels Hearing Level; Bi, Bilateral; Uni, Unilateral; SD, Standard Deviation; Q1‒Q3, Quartiles; M, Mean; Min, Minimum value; Max, Maximum value; p, Significance level from the Shapiro–Wilk test; p < 0.05.

Table 5.

Left ear auditory thresholds (dB HL) by frequency in the unilateral and bilateral CI groups.

    M  SD  Q1  Q2  Q3  Min  Max  p 
250 HzBi  18.86  2.74  16.65  19.83  21.33  14.50  21.50  0.065 
Uni  20.53  1.85  20.50  21.17  21.50  17.50  22.83  0.067 
500 HzBi  17.73  2.30  16.16  18.50  18.50  13.50  21.50  0.709 
Uni  17.46  2.39  16.25  18.50  18.74  12.17  19.50  0.008 
1 KHzBi  15.98  2.51  14.50  15.50  16.17  13.50  22.17  0.008 
Uni  16.50  2.82  15.41  15.66  16.50  13.83  23.17  0.002 
2 KHzBi  14.03  1.50  14.17  14.50  14.50  11.50  15.50  0.141 
Uni  14.78  2.69  13.33  14.50  16.00  11.17  19.17  0.864 
3 KHzBi  15.63  1.19  15.50  15.50  15.50  14.17  17.50  0.238 
Uni  15.78  3.18  14.00  15.50  16.66  12.17  21.50  0.365 
4 KHzBi  15.43  1.57  15.50  15.50  16.50  12.83  16.83  0.200 
Uni  16.39  7.33  11.50  15.50  16.50  11.17  32.09  0.006 
6 KHzBi  14.43  1.47  13.17  15.50  15.50  12.50  15.50  0.028 
Uni  19.42  13.51  13.83  14.83  15.33  12.83  50.00  <0.001 

dB HL, Decibels Hearing Level; Bi, Bilateral; Uni, Unilateral; SD, Standard Deviation; Q1-Q3, Quartiles; M, Mean; Min, Minimum value; Max, Maximum value; p, Significance level from the Shapiro–Wilk test; p < 0.05.

Table 6 presents the descriptive statistics of numerical variables related to device usage time by ear for both unilateral and bilateral cochlear implant users.

Table 6.

Datalogging of CI users in unilateral and bilateral groups.

  Side  M  SD  Q1  Q2  Q3  Min  Max  p 
BilateralRight Ear  9.35  5.06  6.27  10.55  13.47  1.20  14.70  0.153 
Left Ear  10.31  4.46  8.17  11.40  13.90  1.20  15.00  0.246 
UnilateralRight Ear  11.71  3.71  10.20  11.35  14.22  6.10  16.50  0.908 
Left Ear  9.66  4.83  6.00  10.90  12.30  0.30  15.00  0.355 

SD, Standard Deviation; Q1-Q3, Quartiles; M, Mean; Min, Minimum value; Max, Maximum value; p, Significance level from the Shapiro–Wilk test; p < 0.05.

Table 7 presents the descriptive statistics of the numerical variables related to performance in decibels (dB) on the Digit Triplet Test for each ear, for both unilateral and bilateral cochlear implant users.

Table 7.

Auditory performance in dB HL on the digit triplet test for unilateral and bilateral CI users.

  Side  M  DP  Q1  Q2  Q3  Min  Max  p 
BilateralRight Ear  2.28  1.30  1.30  2.45  3.17  0.40  4.40  0.794 
Left Ear  2.63  1.22  1.87  2.85  3.30  0.50  4.60  0.912 
UnilateralRight Ear  2.72  0.88  2.20  2.60  2.90  1.80  4.50  0.177 
Left Ear  2.86  1.61  1.50  2.75  4.22  0.90  5.00  0.347 

SD, Standard Deviation; Q1-Q3, Quartiles; M, Mean; Min, Minimum value; Max, Maximum value; p, Significance level from the Shapiro–Wilk test; p < 0.05.

Regarding the inferential comparative tests, no differences were observed between groups when comparing unilateral and bilateral cochlear implant users, using Student’s t-tests for normally distributed data and Mann–Whitney tests for non-normally distributed data. The results can be found in detail in Tables 8 and 9. Effect size analysis indicated moderate differences between groups for the speech-in-noise variables in the right ear. Moderate effect sizes were also observed at frequencies of 250 Hz, 3 kHz, and 4 kHz in the right ear, and at 2 kHz in the left ear. Additionally, the variable at 250 Hz in the left ear and the usage time of the device in the right ear demonstrated differences with large effect sizes.

Table 8.

Right Ear results of inferential analyses between unilateral and bilateral groups.

  Statistic  df  p  Effect Size (r)  Interpretation 
Usage Timea  −0.991  14  0.339  −0.512  Large 
Speech in Noisea  −0.788  15  0.443  −0.388  Moderate 
250 Hza  −0.889  14  0.389  −0.459  Moderate 
500 Hza  −0.134  16  0.895  −0.063  Low 
1 KHzb  43.000  ‒  0.824  0.075  Low 
2 KHza  −0.248  19  0.807  −0.108  Low 
3 KHza  0.662  17  0.517  0.304  Moderate 
4 KHza  0.807  16  0.432  0.380  Moderate 
6 KHzb  35.500  ‒  1.000  −0.014  Low 

a Student’s t-test; b Mann–Whitney test; Statistic, Test statistic used; df, Degrees of freedom; p, Significance level of the comparative test; Effect Size, Effect size estimate, Cohen’s d for the Student’s t-test and point-biserial correlation for the Mann–Whitney test.

Table 9.

Left Ear results of inferential analyses between unilateral and bilateral groups.

  Statistic  df  p  Effect Size (r)  Interpretation 
Usage Timea  0.302  17  0.767  0.139  Low 
Speech in Noisea  −0.349  16  0.732  −0.165  Low 
250 Hza  −1.542  17  0.142  −0.708  Large 
500 Hza  0.253  18  0.803  0.113  Low 
1 KHzb  30.500  ‒  0.627  −0.153  Low 
2 KHza  −0.560  10  0.588  −0.328  Moderate 
3 KHza  −0.100  10  0.922  −0.059  Low 
4 KHza  −0.285  10  0.781  −0.167  Low 
6 KHzb  18.000  ‒  1.000  0.029  Low 

a Student’s t-test; b Mann–Whitney test; Statistic, Test statistic used; df, Degrees of freedom; p, Significance level of the comparative test; Effect Size, Effect size estimate, Cohen’s d for the Student’s t-test and point-biserial correlation for the Mann–Whitney test.

Discussion

The application of Remote Check proved to be positive by presenting a novel approach for patient monitoring in clinical practice.

Based on our study, 11 individuals with prelingual hearing loss and 20 with postlingual hearing loss were identified. When comparing individuals using bilateral CIs, prelingual participants demonstrated better performance on the speech-in-noise test. According to Bugannim,12 speech understanding in noise can be achieved by cochlear implant users with pre-lingual hearing loss, provided that this ability is developed through auditory training, potentially reaching performance levels comparable or close to those of normal-hearing individuals.

Regarding the prelingual group, it is known that the prognosis after implantation can vary across multiple factors. In the study by Forli,13 for example, participants were tested post-implantation using disyllabic word recognition tasks and obtained results ranging from 0% to 100% in quiet and from 0% to 80% in noise. Such variability in performance can be attributed to a range of factors, including the age at onset of hearing loss, age at initiation of hearing aid use, residual hearing, education level, motivation, and psychological aspects.

For postlingual hearing loss, the present study demonstrated better performance in speech-in-noise tests for individuals using unilateral cochlear implant. In these cases, according to Jaiswal,14 in a study conducted with 21 individuals with severe to profound bilateral post-lingual hearing loss, the findings showed significant improvement in speech intelligibility for patients who were implanted even many years after the onset of deafness, reinforcing that implantation in postlingual adults can yield favorable outcomes. Another factor contributing to good auditory performance in noisy environments may also be related to auditory memory, which, according to Prince,15 besides enhancing speech intelligibility, may extend its benefits to broader aspects of quality of life. When investigating quality of life, Rostkowska16 found results indicating that cochlear implants can also benefit this population by improving aspects such as independence, mental health, happiness, self-esteem, relationships, and others.

For the assessment of auditory thresholds between individuals with unilateral and bilateral cochlear implants, significant difference was observed at certain frequencies for both groups, as well as moderate to high effects at specific frequencies. In other words, a noticeable and relevant difference was found between the tested groups, which, in practical terms, may become more perceptible with an increased sample size and greater homogeneity between groups.

According to Sorrentino,17 Remote Check is an important tool that can be used to assess auditory thresholds and may also be useful for comparing frequency-specific auditory thresholds in acoustic booth settings, allowing for testing of the cochlear implant microphone’s functionality, which cannot be evaluated via Remote Check. Additionally, the microphone may deteriorate over time due to dust, damage, or moisture, potentially leading to reduced performance.

This study also found that the mean auditory thresholds obtained via Remote Check (RC) ranged from 14.03 Db to 21.66 dB. This result demonstrates that cochlear implant users exhibit lower auditory thresholds, which is favorable, as a lower intensity level in dB facilitates access to softer sounds due to the electrical stimulation provided by the CI combined with the mapping adjustment parameters.18,19 This finding is also supported by Chang,20 whose study with 20 implanted adults showed improved speech perception when auditory thresholds were between 25 and 35 dB.

Lower auditory thresholds not only facilitate access to softer sounds but also allow cochlear implant users to reduce listening fatigue and effort, provided these aspects are addressed in auditory training.21 Along with the reduction in listening effort, the resulting benefits can be observed as improved listening performance both in quiet conditions and in noisy environments.22

These data can guide the audiologist in establishing more precise protocols when mapping the cochlear implant of their patients, aiming to optimize the parameters to enhance its use and performance. In addition, teleconsultation can be a viable option to assess the need for adjustment changes in individual cases before scheduling an in-person appointment to carry out the procedure.23

Regarding Cochlear Implant (CI) usage time, when analyzing usage per ear among participants with bilateral CIs, the average usage time was 9.35-hs for the right ear and 10.31-hs for the left ear. Among participants using a CI in only one ear, the average usage time was 11.71-hs for the right ear and 9.66-hs for the left ear. Busch24 analyzed datalogging information from 1,501 patients and found an average CI usage time of 10.7-hs, which is consistent with our findings and supports the recommendation that daily CI processor use of at least 10-hs per day leads to better outcomes.

In the study by Lindquist,25 an average CI usage time of 12-hs per day was found for most adults during the first year after activation, which resulted in better speech comprehension performance compared to those who did not use the device consistently. Such findings may be relevant for decision-making and for providing guidance on strategies to further increase cochlear implant usage time.

In terms of the Digit Triplets Test (DTT), which aims to assess speech comprehension in noise, the average Signal-to-Noise Ratio (SNR) performance ranged from 2.28 dB to 2.86 dB, with a minimum of 0.4 dB and a maximum of 5 dB. In a study conducted by Maruthurkkara8 with 32 participants, the mean DTT result was 1.6 dB, which supports our findings regarding the ease with which participants were able to handle the test and achieve the reported performance levels. According to Rosendahl,26 one factor that may explain the participants’ facility in performing this task is that the DTT is a closed-set test, meaning that the response options are limited: the digits that could appear in the three-digit sequences ranged only from 0 to 9. Another justification, according to Kaandorp,27 is that beyond being a closed-set task, the test consists of familiar and easily recognizable words, allowing the DTT to be used as a speech recognition test for CI users who are unable to perform more complex tasks.

The scoping review by Van den Borre28 on recent studies in this field supports the notion that the Digit Triplets Test (DTT) is a reliable and valid tool for remotely measuring auditory performance and listening abilities in cochlear implant users, in addition to allowing its application in a diverse population with varying characteristics.

Despite these results, there is a scarcity of studies in the literature that investigate the association of the Digit Triplets Test (DTT) with cochlear implants in a remote context. Cullington,29 when testing whether the DTT could be an effective and acceptable method for assessing speech recognition in CI users under conditions similar to a home environment, concluded that most CI users who participated in the study were able to complete the DTT to assess their speech recognition in a simulated home setting. Moreover, the test outcomes showed a strong correlation with other assessments involving sentence comprehension both in quiet and in adaptive noise conditions in clinical settings. In addition, compared with in-person testing, the participants in that study found the remote procedure more practical due to time optimization and the elimination of the need to travel to the clinic.

The literature presents several methods for assessing speech comprehension in Cochlear Implant (CI) users in the presence of competing noise. One such method is the Hearing In Noise Test (HINT), a validated test available in multiple languages with standardized procedures, which evaluates speech recognition both in quiet and in the presence of competing noise using recorded male-voice sentences presented to the patient in a sound booth.30 Another test used to assess speech comprehension in noise is the AzBio Sentence Test, which employs longer sentences with fewer contextual cues and recordings from multiple talkers to increase the level of difficulty.31 Willberg,32 in turn, introduced additional tests that may contribute to the assessment of this ability, namely the Finnish Matrix Sentence Test (FMST), Finnish Simplified Matrix Sentence Test (FINSIMAT), and Finnish Digit Triplet Test (FDTT). The latter can be administered remotely, as responses can be easily recorded using an image of a numeric keypad on a touchscreen device, similar to the Remote Check procedure. Therefore, as a way to complement the remote administration of the DTT via Remote Check, other tests simulating listening and speech comprehension in noise beyond digit-based stimuli could be incorporated into the platform to provide more comprehensive results and allow comparisons across additional domains.

When comparing usage performance between unilateral and bilateral CI users, no statistically significant difference was found, despite the effect size varying from moderate to large across the compared conditions. One possible explanation for this result, as suggested by Philips,21 may be the sample variability, which differed in number and age range between the participant groups. Therefore, further studies are recommended to reaffirm the importance of Remote Check as a tool for remote monitoring of cochlear implant users.

Regarding the general use of the RC, some patients may benefit more from its utilization. Individuals who have been using CI for over one year tend to present stable auditory outcomes and typically attend annual appointments primarily for implant monitoring. For this population, the use of Remote Check can serve as a solution for certain routine consultations, allowing patients to extend the interval between in-person visits. In cases of remote follow-up where a critical issue is detected via RC, the clinician can provide guidance or request an in-person clinical evaluation, as is also recommended for patients with special needs.33

On the other hand, despite the benefits of Remote Check, some limitations should also be considered. According to Sucher,34 the educational level of CI users may interfere with the completion of remote tests due to a lack of familiarity with computers and smartphones, as well as concerns and doubts related to the privacy and security of the tool. Consequently, audiologists may be reluctant to recommend this function to this population.

Another consideration is the possible need for a dedicated professional responsible for ensuring the effective execution of the procedure. This would guarantee that CI users complete all steps of the Remote Check tool, as well as verify that the data have been properly collected in the performance report.35

Nonetheless, Remote Check can be regarded as a valuable tool to be incorporated into clinical practice by audiologists working in auditory rehabilitation and cochlear implantation. The use of Remote Check has the potential to optimize both the clinician’s workflow and facilitate device usage for CI users in their daily routines. The instrument can complement the audiologist’s work by optimizing appointments and enabling remote monitoring of these individuals in cases where in-person consultations are not feasible for various reasons.

Future evidence-based investigations should be conducted to further support the use of Remote Check in clinical routines.

Final considerations

The study had some limitations: participants were not stratified by age group, degree of hearing loss, and educational level was not considered to assess its impact on Remote Check performance. The sample size was limited, as many invited individuals did not complete the process due to mobile connectivity issues. No validated questionnaire was applied to participants after Remote Check to obtain their level of acceptance of the tool. Additionally, the tool does not assess binaural performance, since it evaluates only one ear at a time, even for bilateral cochlear implant users.

Conclusion

Remote Check is an effective tool that can assist in profiling Cochlear Implant (CI) users. Through this tool, it is possible to characterize CI users both in the assessment of auditory thresholds and in speech understanding in noise. The tool can also help to monitor and document patient's progress throughout their daily routine.

ORCID ID

Fernanda Ferreira Caldas: 0000-0003-3728-779X

Financial support

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Data availability statement

The authors declare that all data are available in repository.

Declaration of competing interest

The authors declare no conflicts of interest.

Acknowledgments

None.

References
[1]
A.L.F. Borges, J.S. Silva, V.L. Souza, V.P.M. Ferreira, J.T. Oliveira, T.M. Santos.
Cochlear implant and tinnitus - a meta-analysis.
Braz J Otorhinolaryngol., 87 (2021), pp. 353-365
[2]
A. Gatto, M. Tofanelli, G. Valentinuz, et al.
Cochlear implant cost analysis in adults: a European narrative review.
Eur Arch Otorhinolaryngol., 281 (2024), pp. 4455-4471
[3]
J.A. Skidmore, K.J. Vasil, S. He, A.C. Moberly.
Explaining speech recognition and quality of life outcomes in adult cochlear implant users: complementary contributions of demographic, sensory, and cognitive factors.
Otol Neurotol., 41 (2020), pp. e795-e803
[4]
P. Ryćko, M. Rogowski.
Speech recognition and speech audiometry parameters in evaluation of aural rehabilitation progress in cochlear implant patients: review.
Pol J Otolaryngol., 78 (2024), pp. 1-6
[5]
P.A. Samuel-Sierra, M.V.S. Goffi-Gomez, A.T.M. Magalhães, R.F. Bento, R.K. Tsuji.
Feasibility of self-programming of the speech processor via remote assistant fitting in experienced cochlear implant users.
Int Arch Otorhinolaryngol., 29 (2025), pp. e001-e010
[6]
F.F. Caldas, B.C. Buzo, J.P. Masiero, et al.
Novel cochlear implant assessment tool: comparative analysis of children and adults.
Front Neurol., 14 (2023),
[7]
C. Chen, M.A. Stein, M.L. Hughes, D.J. Morris, L.M. Litvak, D.M. Zeitler.
Testing speech perception with cochlear implants through digital audio streaming in a virtual sound booth: a feasibility study.
J Am Acad Audiol., 32 (2021), pp. 219-228
[8]
S. Maruthurkkara, S. Case, R. Rottier.
Evaluation of Remote Check: a clinical tool for asynchronous monitoring and triage of cochlear implant recipients.
Ear Hear., 43 (2022), pp. 495-506
[9]
H.A. Miot.
Assessing normality of data in clinical and experimental trials.
J Vasc Bras., 16 (2017), pp. 88-91
[10]
E. Brunner, A.C. Bathke, F. Konietschke.
Rank and pseudo-rank procedures for independent observations in factorial designs.
Springer International Publishing, (2018),
[11]
C.C. Serdar, M. Cihan, D. Yücel, M.A. Serdar.
Sample size, power and effect size revisited: simplified and practical approaches in pre-clinical, clinical and laboratory studies.
Biochem Med (Zagreb)., 31 (2021), pp. 27-53
[12]
Y. Bugannim, D.A.E. Roth, D. Zechoval, L. Kishon-Rabin.
Training of speech perception in noise in prelingual hearing-impaired adults with cochlear implants compared with normal-hearing adults.
Otol Neurotol., 40 (2019), pp. e316-e325
[13]
F. Forli, F. Lazzerini, V. Montecchiari, R. Morganti, L. Bruschini, S. Berrettini.
Cochlear implant in prelingually hearing-impaired adults: prognostic factors and results.
Acta Otorhinolaryngol Ital., 41 (2021), pp. 173
[14]
A.S. Jaiswal, R. Kumar, R. Kumar, A.K. Kairo, S. Raveendran, P. Sagar.
Cochlear implantation in adults with post-lingual hearing loss: clinico-demographical study and outcomes in the current times.
Indian J Otolaryngol Head Neck Surg., 75 (2023), pp. 548-551
[15]
P. Prince, J. Chen, T. Le, V. Lin, A. Dimitrijevic.
Greater working memory in cochlear implant users is related to higher subjective quality of life.
Front Audiol Otol., 2 (2024),
[16]
J. Rostkowska, P.H. Skarżyński, J. Kobosko, E. Gos, H. Skarżyński.
Health-related quality of life in adults with profound postlingual hearing loss before and after cochlear implantation.
Eur Arch Otorhinolaryngol., 278 (2021), pp. 3393-3399
[17]
F. Sorrentino, D. Cazzador, F. Gazzola, et al.
Remote Check as a tele-health instrument for cochlear implant recipients: analysis of impact and feasibility of application.
Am J Otolaryngol., 45 (2024),
[18]
U. Rüegg, A. Dalbert, D. Veraguth, C. Röösli, A. Huber, F. Pfiffner.
Correlation between speech perception outcomes after cochlear implantation and postoperative acoustic and electric hearing thresholds.
J Clin Med., 10 (2021), pp. 324
[19]
N.H. Capach, N. Zigdon, T.A. Payne, et al.
Cochlear implants and the aided audiogram: a retrospective study comparing performance across device manufacturers.
Audiol Res., 15 (2025), pp. 79
[20]
C.J. Chang, H.J. Sun, C.J. Hsu, Y.C. Chiu, J.K. Yu, Y.C. Wu.
Cochlear implant mapping strategy to solve difficulty in speech recognition.
J Chin Med Assoc., 85 (2022), pp. 874-879
[21]
C. Philips, L. Jacquemin, M.J.W. Lammers, et al.
Listening effort and fatigue among cochlear implant users: a scoping review.
Front Neurol., 14 (2023),
[22]
M.W.R. Voola, D. Tavora-Vieira, A. Wedekind, C. Bogdanov, A. Acharya.
Auditory listening effort and reaction time: a comparative study between single sided deaf cochlear implant users and normal hearing controls.
Front Audiol Otol., 2 (2024),
[23]
A.T.M. Magalhães, M.V.S.G. Gomez, R.K. Tsuji, R.F. Bento.
Technology supporting continuing education in cochlear implantation.
Audiol Commun Res., 26 (2021), pp. e2511
[24]
T. Busch, F. Vanpoucke, A. Van Wieringen.
Auditory environment across the life span of cochlear implant users: insights from data logging.
J Speech Lang Hear Res., 60 (2017), pp. 1362-1377
[25]
N.R. Lindquist, M.S. Dietrich, A. Patro, et al.
Early datalogging predicts cochlear implant performance: building a recommendation for daily device usage.
Otol Neurotol., 44 (2023), pp. e479-e485
[26]
B.G. Rosendahl, T.V. Tronstad, J. Øygarden.
Development and evaluation of the Digit Triplet Test in Swahili language.
S Afr J Commun Disord., 72 (2025),
[27]
M.W. Kaandorp, C. Smits, P. Merkus, S.T. Goverts, J.M. Festen.
Assessing speech recognition abilities with digits in noise in cochlear implant and hearing aid users.
Int J Audiol., 54 (2015), pp. 48-57
[28]
E. Van den Borre, S. Denys, A. van Wieringen, J. Wouters.
The digit triplet test: a scoping review.
Int J Audiol., 60 (2021), pp. 946-963
[29]
H.E. Cullington, T. Aidi.
Is the digit triplet test an effective and acceptable way to assess speech recognition in adults using cochlear implants in a home environment?.
Cochlear Implants Int., 18 (2017), pp. 97-105
[30]
J. Buisson Savin, P. Reynard, E. Bailly-Masson, et al.
Adult normative data for the adaptation of the hearing in noise test in European French (HINT-5 Min).
Healthcare (Basel), 10 (2022),
[31]
X. Xi, Y. Wang, Y. Shi, et al.
Development and validation of a Mandarin Chinese adaptation of AzBio sentence test (CMnBio).
Trends Hear., 26 (2022),
[32]
T. Willberg, V. Sivonen, P. Linder, A. Dietz.
Comparing the speech perception of cochlear implant users with three different Finnish speech intelligibility tests in noise.
J Clin Med., 10 (2021),
[33]
D. Brotto, E. Caserta, F. Sorrentino, et al.
Long-term impedance trend in cochlear implant users with genetically determined congenital profound hearing loss.
J Am Acad Audiol., 33 (2022), pp. 105-114
[34]
C. Sucher, R. Norman, E. Chaffey, R. Bennett, M. Ferguson.
Patient preferences for remote cochlear implant management: a discrete choice experiment.
PLoS One, 20 (2025),
[35]
M.A. Ferguson, R.H. Eikelboom, C.M. Sucher, D.W. Maidment, R.J. Bennett.
Remote technologies to enhance service delivery for adults: clinical research perspectives.
Semin Hear., 44 (2023), pp. 328-350
Copyright © 2026. The Authors
Download PDF
Brazilian Journal of Otorhinolaryngology (English Edition)
Article options
Tools