Vestibular evoked myogenic potentials (VEMP) have been used in complementary otoneurological assessment, but the use of VEMP in clinical settings is limited. VEMPs can be used to assess vestibular function, particularly of the saccule, the inferior vestibular nerve, and/or the vestibular nucleus.
ObjectiveTo verify the highest possible - and reliable - stimulation rate to obtain VEMPs.
MethodThe VEMPs of 18 subjects were acquired using stimulation rates ranging between 5.1 and 40.8 stimuli per second. Study design: cross-sectional contemporary cohort study.
ResultsLatencies were kept unaltered and amplitudes were progressively reduced as stimulation rates were increased. However, ANOVA and the Kruskal-Wallis test failed to find statistically significant differences between the tested parameters. The study further indicated that when stimulation rates of 5.1 and 10.2 stimuli per second were compared, no statistically significant differences were observed in latency.
ConclusionThe highest reliable stimulation rate observed in the group of young adults with normal hearing included in this study was 10.2 stimuli per second.
Vestibular evoked myogenic potentials (VEMP) have been used in the complementary assessment of vestibular function, particularly of the saccule, the inferior vestibular nerve, and/or the vestibular nucleus1–6.
Responses are captured from neck muscles through surface electrodes. The tracings derived from acoustic stimulation are made up of two complexes of two-phase waves: p13 and n231,7–11. VEMPs can be obtained from air, bone, and galvanic acoustic stimulation4.
Response characteristics are correlated to the type of stimulation and frequencies used. Tone bursts11–15 or clicks16,17 can be used in acoustic stimulation. Lower frequencies produce more homogeneous responses, with 500 Hz6,12,18–20 as the most effective frequency. Response is analyzed by the selection of peaks and assessment of amplitudes and latencies21,22.
In the clinical setting, VEMP testing presents a series of favorable traits, as it is an objective, non-invasive, easy-to-perform test that does not bring discomfort to patients3,14. However, there is no agreed standard to obtain VEMPs, and a wide array of methods and protocols have been used23. The most frequently described stimulation rate is 5 Hz. Nonetheless, higher rates, if reliable, would expedite the testing protocol.
This study aims to find the highest reliable stimulation rate to obtain VEMPs.
METHODThis study was approved by the institution's Research Ethics Committee and given permit 990/09. All participants signed informed consent terms before joining the study.
Eighteen individuals (36 ears) were enrolled in the study as per the following criteria: ages between 18 and 35 years and auditory thresholds equal to or lower than 20 dBNA with differences between ears per frequency of 10 dB or under. The number of participants was calculated based on the sample size for an infinite population with an alpha of 0.05, a standard deviation of 9 µV and tolerable error of 3 µV.
Individuals exposed to occupational or leisure noise, previously submitted to middle or inner ear surgery, with more than three cases of outer or middle ear infection in the current year, prior use of ototoxic medication, presence of systemic alterations conducive to vestibulocochlear involvement such as diabetes, high blood pressure, hormonal disorders, and presence of tinnitus, vertigo, dizziness or other vestibulocochlear alterations were excluded.
Participants were asked to answer a questionnaire for screening purposes. The following procedures were then carried out: otoscopic examination, pure-tone audiometry, and VEMP testing.
Surface electrodes positioned on the subjects' skin were used to record VEMPs. The positive electrode was placed on the middle third of the sternocleidomastoid (SCM) muscle on the side where stimulation was applied; the negative electrode was positioned at the level of the tendon of the SCM, just above the clavicle; and the ground electrode was placed on the frontal middle line. Patients were seated during the acquisition of SCM records, with their heads in maximum lateral rotation turned to the opposite side of stimuli application.
In VEMP examination, the mean value for 200 tone burst stimuli at 500 Hz was calculated, with stimulation rates set at 5.1, 10.2, 20.4, and 40.8 stimuli per second at an intensity of 95 dBNAn with subjects wearing ER-A3 ear buds. A pass-band filter (5-1000 Hz) with exhibition of 10 to 25 µV per division was used. Stimulation rates were not set as integer numbers in order to prevent potentials from being acquired in phase with the frequency of the Brazilian grid, set at 60 Hz24,25. Records were captured in 40 ms windows to encompass all responses14,15.
Wave morphology was used in the interpretation of test findings. Waves p13 and n23 were delimited by the latencies of the first positive and negative peaks by two authors/examiners. Discrepancies between authors/examiners were resolved by a third author/examiner.
Statistical methodThe data sets were treated and processed using application Predictive Analytics SoftWare (PASW® Statistic) release 17.0. Mean values were presented in tables and graphs, along with standard deviations and percentile distributions.
Latency and amplitude normality for waves p13 and n23 was analyzed through the Kolmogorov-Smirnov test. ANOVA was used to compare latencies and amplitudes at different stimulation rates (5.1, 10.2, 20.4, and 40.8 stimuli per second) obtained in VEMP testing, and pairs were compared using the Tukey or the Kruskal-Wallis test depending on whether the samples followed a normal distribution or not, respectively. The Mann-Whitney test was used to further analyze amplitudes, with the purpose of comparing stimulation rates and check for statistically significant differences. Statistical significance was attributed to events with p ≤ 0.05; a beta error of 0.1 was admitted.
RESULTSThe sample included 18 subjects (36 ears), 12 females (24 ears) and six males (12 ears). The individuals were aged between 21 and 27 years, and had a mean age of 23.03 ± 1.33 years.
VEMPs were recorded through stimulation and unilateral data acquisition. Proper morphology was attained in 100% of the ears using a stimulation rate of 5.1 stimuli per second; in 96.87% at 10.2 stimuli per second; in 86.11% at 20.4 stimuli per second; and in 72.22% at 40.8 stimuli per second. Tone bursts at 500 Hz were used in acoustic stimulation.
The Kolmogorov-Smirnov revealed latencies and amplitudes followed a normal distribution pattern, except for the latencies seen in wave p13 for stimulation rates of 10.2 and 40.8 stimuli per second. Non-parametric tests were thus used.
The waves were delimited in the test tracings and absolute latencies and amplitudes were determined for waves p13 and n23. Table 1 shows the data related to these parameters for each stimulation rate irrespective of ear.
VEMP latencies and amplitudes for each stimulation rate.
Latency (ms) | Amplitude (µV) | ||||
---|---|---|---|---|---|
p13 | n23 | p13 | n23 | ||
5.1 stimuli per second | Mean | 14.10 | 24.80 | 260.43 | -328.72 |
SD | 1.99 | 2.43 | 5.68 | 8.22 | |
10.2 stimuli per second | Mean | 14.11 | 24.65 | 77.03 | -103.11 |
SD | 2.15 | 2.52 | 3.53 | 1.80 | |
20.4 stimuli per second | Mean | 14.20 | 24.20 | 60.12 | -86.93 |
SD | 2.74 | 3.18 | 2.43 | 3.71 | |
40.8 stimuli per second | Mean | 14.84 | 24.11 | 27.92 | -23.42 |
SD | 2.71 | 4.12 | 2.15 | 2.57 | |
p-value | 0.19** | 0.54* | 0.06* | 0.14* |
Table 1 shows that the p13 and n23 wave latencies were kept constant and amplitudes decreased gradually as stimulation rates were increased. However, ANOVA and the Kruskal-Wallis test failed to reveal statistically significant differences between parameters.
Amplitudes were further analyzed by comparing stimulation rates. The Mann-Whitney test revealed statistically significant differences for wave p13 between stimulation rates of 5.1 and 20.4 stimuli per second (p = 0.03), and 5.1 and 40.8 stimuli per second (p = 0.01). For wave n23, amplitudes were statistically different only when stimulation rates of 5.1 and 40.8 stimuli per second were compared (p = 0.02), with no significant differences seen between stimulation rates of 5.1 and 20.4 stimuli per second (p = 0.06).
Graph 1 shows a comparison between amplitudes at different stimulation rates.
DISCUSSIONThe results seen in the studied population showed that it is possible to consistently acquire records for waves p13 and n23 in the time domain on all analyzed stimulation rates, as similarly reported by other authors15,26.
The VEMP latency and amplitude results at a stimulation rate of 5.1 stimuli per second seen in this study were similar to the values reported in the literature6,27. As for other stimulation rates, reports in the literature indicate that latency and amplitude tend to decrease as the stimulation rate is increased - a finding in disagreement with this study when latency is considered15,26.
Some authors have related the decrease in amplitude consequent to stimulation rate increases to possible SCM muscle fatigue during testing, as subjects are required to produce effective muscle contraction in order to allow for proper recording of potentials. Thus, the longer the tests, the lower the amplitude27. Others have described the reduction in amplitude as a consequence of reflex habituation, as the high rate of stimulation exhausts sensory cells and delays the activation of the first neuron28–30. However, in order to prevent tested individuals from getting tired and to avoid SCM muscle fatigue, the subjects included in this study were asked to rest for one minute between each data acquisition cycle, i.e., when stimulation rates were changed, to prevent muscle fatigue and habituation from occurring.
No statistically significant differences were seen in latency when stimulation rates of 5.1 and 10.2 stimuli per second were compared, as also reported by other authors15,26. However, most choose a rate of five stimuli per second, as it allows for more consistent data acquisition and easier identification of tracings26.
Lastly, the rate of 10.2 stimuli per second appears to be more adequate in clinical applications as it produces waves with more adequate morphology, with equal tracing identification and amplitudes which are not statistically different when compared to the rate of five stimuli per second, in addition to being visible to the naked eye. Additionally, tests performed at a rate of 10.2 stimuli per second reduce patient discomfort and data acquisition times15. Further studies with larger populations are yet required to confirm the adjustments recommended for the testing protocol.
CONCLUSIONThe highest reliable stimulation rate observed for the population included in this study was 10.2 stimuli per second.
Paper submitted to the BJORL-SGP (Publishing Management System – Brazilian Journal of Otorhinolaryngology) on August 31, 2012; and accepted on May 29, 2013. cod. 10431.